ATRKOZ PDF Print E-mail


Textile Active Smoke Barrier (ASB)

FIRE RESISTANCE:
D60

 

Kliknutím fotografii otevřeteKliknutím fotografii otevřeteKliknutím fotografii otevřete

 

The textile active smoke barrier ATRKOZ is designed to divide the building in smoke zones in case of fire, and prevents consequential smoke spread to other areas. The barrier is designed as a vertically sliding shutter.

This active smoke barrier is advantageous for minimum spatial requirements, since under normal conditions it is coiled in a cover that is placed in such a manner not to obstruct normal operation (usually above the floor).

The main quality required from these smoke barriers is their fire resistance. Textile active smoke barriers ATRKOZ have fire resistance D 60 (the device is designed in accordance with CSN EN 12101-1).

This smoke barrier ATRKOZ was successfully tested in the FIRES s.r.o. test institute, and was granted the CE certificate No. 1396-CPD-0027.
Kliknutím certifikát zvětšíte
The manufacturer issues Declaration of Conformity for individual commissions, within the interpretation of Act No. 22/1997 Coll., as amended.


Technical properties
  • The shutter is made of a special fire-resistant textile, filled up with glass fibres with surface coating (0.4 mm thickness).
  • The design allows the shutter to be placed on an opening or into it (or combination of both variants, as the case may be), without any additional special structures, fixation in concrete, masonry or steel profiles.
  • The shutter can be connected in a line, which can create unlimited lengths of barriers.
  • The standard dimension of the winding box is 205 x 210 mm, for bigger barrier dimensions the size of the box is 205 x 405.
  • The smoke barrier is controlled electrically by means of a tube drive (electric motor with gearbox and gravitation start-up).
  • It allows automatic closing from the EPS switchboard (potential-free contact), even in case the supply voltage by means of gravitation drops out.
  • Electronic control of individual functions of the smoke barrier proceeds by means of a special AOP control unit, including control elements (buttons or key control).
  • Local autonomous fire sensors, optical and acoustic signalling can be supplied together with the shutter.
  • Textile shutters have a very low weight (textile = 0.45kg/m2).
  • The speed of the shutter closing is approx. 100 mm/s.
  • All visible steel parts of the barriers are painted in a shade according to the RAL sampler.
 

Contact

AVAPS, s. r. o
U Obalovny 488
250 67 Klecany
Czech republic

tel.: 284 688 545
fax: 266 311 828

HOT LINE:
+420 777 911 780
+420 607 703 098

e-mail: obchod@avaps.cz

IČ: 25650939
DIČ: CZ25650939

Banking relation:
ČSOB, Praha 1

Account numbers:
CZK 579052693/0300
EUR 200094902/0300

Co-operation

Noano.cz